What it is about

Those who supply the general public must be able to prove it

Since December 2025, the BSI Act no longer refers to critical infrastructures but to critical facilities. Their operators are always particularly important entities – so all NIS2 obligations apply to them as well. In addition, there are three requirements that go beyond the general level: an enhanced level of protection for the systems that are decisive for the functioning of the facility, the use of attack detection systems and regular evidence to the BSI.

Since March 2026, the KRITIS Umbrella Act (KRITIS-Dachgesetz) has supplemented these obligations with minimum standards for physical resilience.

  • 3 yearsEvidence cycleEvidence to the BSI through security audits, inspections or certifications (Section 39 BSIG)
  • § 31 BSIGAttack detectionContinuous, automatic collection and analysis of characteristics from ongoing operation
  • 24/7Contact pointContact point for the BSI that is reachable at all times

Does this affect us?

A facility is critical if it is significant for the provision of a critical service and reaches the threshold of the BSI Critical Infrastructure Ordinance (BSI-Kritisverordnung). The standard value is the supply of 500,000 persons. The sectors include energy, water, food and health, among others.

It is the facility that is covered, not the company: a utility can be the operator of a critical facility with a waterworks or a wastewater treatment plant and, with the rest of its operations, “only” a particularly important entity.

The industry-specific standard is worthwhile even below the threshold. It describes the state of the art for the industry – and is therefore the obvious benchmark for the NIS2 implementation, including for smaller utilities.

Industries

Typical fields of action

Industry Benchmark Common gaps
Water supply Industry-specific security standard for water/wastewater (B3S) (DVGW W 1060) with security compendium Attack detection ends at the office IT, unmanned outstations, remote access during on-call duty
Wastewater Industry-specific security standard for water/wastewater (B3S) (DWA-M 1060) with security compendium Flat process networks, pumping stations via mobile radio, scope excluding sewer network control
Energy supply IT security catalogue of the Federal Network Agency (Bundesnetzagentur) under Section 5c EnWG Certified scope does not cover generation and ancillary facilities, delimitation from facilities under the BSI Act
Industry with self-supply Case-by-case review Own power plants, waterworks or wastewater treatment plants that also supply third parties have not been assessed

Special case: energy

For operators of energy supply networks, energy installations and digital energy services, Sections 5c to 5e of the German Energy Industry Act (EnWG) apply instead of Sections 30 to 32 and 39 BSIG. The requirements are set by the Federal Network Agency (Bundesnetzagentur) in the IT security catalogue; the obligations to register and report to the BSI remain. The Federal Network Agency (Bundesnetzagentur) is revising the catalogues in the course of the NIS2 implementation and intends to align them more closely with ISO/IEC 27001. Until the new version is issued, the existing catalogues continue to apply to network and installation operators.

Services

Specifics for each service phase

Built on our service model – this is what is added for critical facilities.

1. Enable

  • Briefing for plant management and executive management on operator obligations and evidence procedures
  • Training on the industry-specific standard and its application in control technology
  • Training for the contact point and on-call staff: detect, assess, report

GoalEmbed operator obligations and evidence procedures in the organisation

2. Assess

  • Review of facility categories and thresholds
  • Delimitation of the scope: which systems are decisive for functioning?
  • Gap analysis against the industry-specific standard or the IT security catalogue
  • Maturity assessment of attack detection

GoalClarity about facilities, scope and distance to the industry-specific standard

3. Implement

  • Protection concept for control system, telecontrol technology and outstations
  • Concept for attack detection systems in OT: logging, detection, response
  • Vendor-independent OT security engineering and tendering of the components
  • Emergency and recovery planning for the critical service

GoalEnhanced level of protection for the systems on which supply depends

4. Demonstrate

  • Internal audit before the inspection
  • Evidence documentation according to the BSI’s specifications
  • Support during the inspection by the auditing body
  • Remediation plan and follow-up

GoalEvidence without security deficiencies that have to be reworked

5. Sustain

  • Annual update of the supply figures and the reported data
  • Operational support for attack detection: analysis, adjustment of rules, reporting
  • Security assessment of changes to the critical facility
  • Preparation of the next evidence with an interim audit

GoalStay audit-ready between two pieces of evidence

Interplay

What can be reused

Set of rules Reusable from the KRITIS implementation Remains separate
NIS2 Risk management and reporting process of the critical facility as a template for the rest of the company Scope: the entire entity instead of a single facility
TRBS 1115 Part 1 Segmentation, remote maintenance concept, monitoring and emergency management Protection of persons, freedom from interference with safety devices
ISMS A certificate can be the basis of the evidence if the scope fully covers the critical facility Attack detection and industry-specific requirements
KRITIS Umbrella Act Risk analysis, emergency and crisis management Physical protection and separate reporting obligation for incidents

Frequently asked questions

In brief

What changes for already registered KRITIS operators?

The obligations remain essentially the same. What is new are the additional registration as a particularly important entity, the obligations of management and the evidence cycle of three instead of two years.

Does the KRITIS audit also cover the NIS2 scope and NIS2 obligations?

No. The NIS2 scope and NIS2 obligations are not part of the KRITIS audit. As particularly important entities, operators of critical facilities must nevertheless meet the NIS2 obligations and document their implementation separately.

Do we have to apply the industry-specific standard?

No, but it makes the evidence easier. For industry-specific standards, the BSI determines that they are suitable for meeting the statutory requirements. Anyone who deviates from them must justify the equivalence of their measures themselves.

Is a certificate according to ISO/IEC 27001 sufficient?

Only if the scope fully covers the critical facility and the additional requirements – in particular attack detection – are covered.

What does the KRITIS Umbrella Act additionally require?

Measures for physical resilience, for example site protection, resilience against failure and emergency organisation, as well as the reporting of incidents. It supplements the IT security requirements but does not replace them.

Does LeiKon carry out the audit itself?

No. The evidence is provided by an auditing body. We prepare you for it and support the audit.

When is your next evidence due?

Let us clarify which of your facilities are affected and what must be available by the evidence deadline.

Contact us

As of November 2026. Basis: BSI Act of 2 December 2025 (Sections 28, 30, 31, 33 and 39), BSI Critical Infrastructure Ordinance (BSI-Kritisverordnung), KRITIS Umbrella Act of 11 March 2026, Sections 5c to 5e EnWG. This page does not constitute legal advice.