Cyber Security for Major-Accident Establishments according to KAS-51
The German Major Accidents Ordinance (Störfall-Verordnung) requires interference by unauthorised persons to be considered as a source of danger – including cyber attacks. We prepare the IT risk assessment and security analysis and prepare the presentation in the safety report.
What it is about
The cyber attack as a cause of major accidents
Under Section 3 of the German Major Accidents Ordinance (Störfall-Verordnung), operators of an establishment must consider interference by unauthorised persons as a source of danger. The KAS-51 guideline of the German Commission on Process Safety (Kommission für Anlagensicherheit) describes how this is done – explicitly including cyber-physical attacks on process and safety control systems. What is protected is the people in the surrounding area and the environment.
The guideline distinguishes two levels: basic measures for all establishments and more extensive protective measures based on a security analysis where there is a particular hazard. For upper-tier establishments, this is usually the case.
- § 3 StörfallVBasic obligationInterference by unauthorised persons must be considered as a source of danger – access, entry and intervention
- 3Components of the security analysisThreat analysis, hazard analysis and IT risk assessment are brought together
- 2 yearsLongest intervalThe IT risk assessment must be repeated regularly and when triggered by events
Does this affect us?
Yes, if your site is a lower-tier or upper-tier establishment. The basic measures apply to all establishments. A security analysis is required if an interference can trigger a serious danger to many people, property damage outside the establishment or severe environmental damage. For installations outside the Major Accidents Ordinance, the guideline can be applied by analogy where the hazard potential is comparable.
The scope covers all components and systems whose manipulation directly or indirectly affects functional safety: safety controllers and the process control system, engineering stations, network transitions – and IT systems outside production from which a connection into the installation can be established.
The authority asks. Immission control authorities examine IT security during inspections and in permit procedures. In North Rhine-Westphalia, the presentation of IT security in the safety report is specified in more detail by a guidance paper of the state environment agency.
Industries
Typical fields of action
| Industry | Typical installations relevant to security | Common gaps |
|---|---|---|
| Chemicals | Reactors, tank farms, filling plants and loading facilities with safety instrumented systems, package units | Safety report without an IT section, IT risk assessment older than two years, engineering station in the operational network, no four-eyes principle for changes to the safety controller |
| Pharmaceuticals and cosmetics | Solvent stores, synthesis plants | Qualified systems without vulnerability management, remote maintenance by plant suppliers |
| Energy and gases | Gas and liquefied gas storage, tank farms | Remotely monitored sites without tamper detection, shared networks for operation and safety |
| Water, wastewater, food | Chlorine gas stores, biogas holders, ammonia refrigeration plants | Relevance to major accidents not assessed, basic measures not documented |
Services
Specifics for each service phase
Built on our service model – this is what major-accident law additionally requires in each phase.
1. Enable
- Briefing for plant management and major-accident officers: obligations, guideline, expectations of the authority
- Target-group-oriented training concept for operations, maintenance and IT
- Instruction of external companies and service providers with access to the plant control system
GoalAnchor IT security as a management task and part of the operational safety culture
2. Assess
- Comparison with the basic measures of the guideline using the control questions
- Decision on whether a particular hazard exists
- Review of the safety report and the safety management system for their link to IT security
- Prioritised roadmap up to the next inspection or update
GoalClarity on whether basic measures suffice or a security analysis is required
3. Implement
- Asset register with responsible persons and protection requirements, network architecture diagram
- IT risk assessment: impact of cyber attacks on the integrity and availability of safety functions according to IEC 61511
- Contribution to the security analysis: bringing together threat and hazard analysis
- Protective measures: separation of IT and OT, access management, tamper detection, protection of mobile devices and data media
- Integration into the safety management system and functional safety management
GoalAn IT risk assessment that follows on from the hazard analysis
4. Demonstrate
- Text contributions on IT security for the safety report and permit documents
- Separation of public and confidential parts of the documentation
- Preparation and support of inspections and expert examinations
- Management of findings
GoalA safety report that answers the authority’s questions
5. Sustain
- Repetition of the IT risk assessment at the defined interval and when triggered by events
- Monitoring of the threat situation, vulnerability and advisory monitoring
- Security assessment in change management
- Updating of documentation and reporting to plant management
GoalKeep the assessment up to date before the authority asks for it
Interplay
What can be reused
| Set of rules | Reusable from implementation according to KAS-51 | Remains separate |
|---|---|---|
| TRBS 1115 Part 1 | IT risk assessment of the safety devices, asset register, protective measures | Protection objective of employees instead of neighbourhood, inspection by the approved inspection body, effectiveness review per installation |
| NIS2 | Asset register, network architecture, training concept, response to vulnerabilities | Reporting obligations to the BSI, applicability to the entire company |
| ISMS | The guideline is based on IT-Grundschutz and recommends integration along the lines of the ISO 27000 series | Link to the major-accident scenarios of the safety report |
| IEC 62443 and NAMUR | Zone model and NAMUR NA 163 as a method for the IT risk assessment | – |
Experience
Proven in establishments of the chemical industry
For a chemical industry group, we supported the selection of the method and carried out the IT/OT risk assessment for the safety reports of its establishments. In doing so, we combine three disciplines that the guideline brings together: process control, functional safety according to IEC 61511 and information security.
Frequently asked questions
In brief
Is KAS-51 binding?
The guideline is not a law. However, it specifies a basic obligation of the Major Accidents Ordinance and serves authorities and experts as a benchmark. Whoever proceeds differently must show that a major accident caused by interference by unauthorised persons is ruled out just as reliably.
Does it also apply to lower-tier establishments?
Yes. The basic measures apply to all establishments. They suffice if they can reasonably rule out a major accident caused by interference by unauthorised persons.
How often must the IT risk assessment be repeated?
Regularly and when triggered by events, for example in the case of new hazards or when components are replaced. The operator defines and justifies the interval; it should not exceed two years.
We already comply with TRBS 1115 Part 1. What is still missing?
The view beyond the factory fence: major-accident scenarios with effects on the neighbourhood and the environment, the bringing together with threat and hazard analysis and the presentation in the safety report. The risk assessment of the safety devices can be used for both sets of rules.
Does LeiKon take over the entire security analysis?
We are responsible for the IT/OT part. Questions of physical site protection and drone defence are handled by plant security or specialised partners; we bring the results together with you.
Is your safety report due for an update?
Let us clarify whether your IT risk assessment is up to date and what the authority expects at the next appointment.
Get in touchAs of November 2026. Basis: German Major Accidents Ordinance (12th BImSchV), Section 3 (2) No. 3; guideline KAS-51 “Measures against interference by unauthorised persons” of the Commission on Process Safety (Kommission für Anlagensicherheit). This page does not constitute legal advice.